MASCO Catalog: Construction Liquid and Powder

Read manufacturers' data sheets for complete specifications, installation procedures, and MSDS precautions. Warning : Chronic health effect possible—inhalation of silica dust may cause lung injury/disease (Silicosis). Take appropriate measures to avoid breathing dust. See page 179-180 for more information. 69 MASONS SUPPLY COMPANY Oregon (800) 537-3407 ♦ Washington (800) 537-6216 ♦ www.MASCO.net Clackamas | Eugene | West Eugene | Hillsboro | Medford | Portland | Salem | Ridgefield | Seattle | Tacoma | Woodinville NC Grout Description : A nonshrink, nonstaining grout. Its multi-flow quality allows this product to be used at various consistencies including pumping into inaccessible areas. NC Grout may be packed, rodded, vibrated, poured, or pumped. It has high compressive and flexural strengths and is non-rusting and non-corrosive. Application : Used interior or exterior to grout structural steel, columns, anchor bolts, precast structural members, and tee joints. Applicable Standards : Corp of Engineer Specifications CRD C-621 and CRD C-588, ASTM C-827 and ASTM C-1107. Coverage : One 50 lb. bag will yield approximately 0.43 ft³ of grout. For applications over 2", extend with 25 lbs. of clean washed 3/8" pea gravel. Yield will be increased to approximately .61 ft 3 . Specifications : @ 72 ° F Compressive Strength (ASTM C-109): Plastic: 3 days 5,500 psi 7 days 7,500 psi 28 days 8,000 psi Flowable: 3 days 3,000 psi 7 days 4,800 psi 28 days 6,000 psi Set Time (ASTM C-191): Plastic: Initial 1.5 to 2.0 hrs Final 3.0 to 4.0 hrs Flowable: Initial: 5.0 to 5.5 hrs Final: 7.0 to 8.0 hrs Application Life: 30 min Thickness Per Lift: ½"–2" neat 2"–6" extended No. Size TAM NC 50 lb. bag, 64/pallet Description : NS GROUT is designed for critical use where high strength, non- staining characteristics and positive expansion are required. NS GROUT contains only natural aggregate and an expansive cementitious binder. It is extremely flowable. When cured, it appears similar to concrete in appearance. • Non-staining natural aggregate for better appearance • Excellent bearing • Compatible with galvanic anodes (Fluid consistency) • Appearance of plain concrete • Does not contain any added chloride ions • Outstanding strength • Initial set time of 3-5 hours • Final set time of 4-6 hours Applications: • Pumps and fans • Compressors & motors • Generators • Machine bases of all types • Anchor bolts • Column baseplates Application Standards: • CRD-C621, Corps of Engineers Specification for Non-Shrink Grout 120% flowable consistency 20-30 seconds fluid consistency • ASTM C 1107, “Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Non- Shrink)” • ASTM C 109, compressive strength 28 days @ 8500 psi flowable consistency Coverage: 50 lb package yields 0.45 ft 3 with 1.2 gal water. For applications 5” or greater, extend with 25 lbs of clean, washed pea gravel. Yield will be increased to approximately 0.60 ft³. Specifications : At 72 ° F Compressive Strength (ASTM C-109): Fluid: 3 days 3500 psi 7 days 5000 psi 28 days 6800 psi Flowable: 3 days 4500 psi 7 days 6000 psi 28 days 8500 psi Set Time (ASTM C-191): Initial 3-5 hrs Final 4-6 hrs Flow Rate (ASTM C939/CRD-C 621): Fluid: 20 to 30 seconds Flowable: 120% Thickness per Lift: 1-5” neat, 5”+ extended with pea gravel No. Size EU NS 50 lb bag, 64/pallet NS Grout GENERAL PURPOSE Grouts

RkJQdWJsaXNoZXIy MTIxNDc=