MASCO Catalog: Construction Liquid and Powder

Read manufacturers' data sheets for complete specifications, installation procedures, and MSDS precautions. Warning: Chronic health effect possible—inhalation of silica dust may cause lung injury/disease (Silicosis). Take appropriate measures to avoid breathing dust. See page 179-180 for more information. 102 MASONS SUPPLY COMPANY Oregon (800) 537-3407 ♦ Washington (800) 537-6216 ♦ www.MASCO.net Clackamas | Eugene | West Eugene | Hillsboro | Medford | Portland | Salem | Ridgefield | Seattle | Tacoma | Woodinville TROWELABLE STRUCTURAL VERTICAL Vertical & Overhead Concrete Repair Description : A 1-component fiber reinforced repair mortar applied by low pressure spray or hand trowel for concrete repairs. Silica fume enhanced. Contains migratory corrosion inhibitor. Freeze-thaw resistant. Application : Vertical and overhead concrete repairs. Interior and exterior use. Bridge, parking garages, and tunnels. Manholes, pipelines, dams and other waste water structures. Thickness Per Lift : ⅜"–2" vertical ⅜"–1" overhead Coverage : One 50 lb. bag yields approximately .45 ft³ and will cover approximately 5.4 ft² @ 1" thickness. Specifications : At 75° F Compressive Strength (ASTM C-109): 1 day 3,200 psi 7 days 6,200 psi 28 days 8,500 psi Shear Bond Strength (ASTM C-882): 28 days 3,250 psi Set Time (ASTM C-266): Initial 1 hr Final 2 hrs Application Life: 30 min Structural Mortar No. Size TAM SM 50 lb. pail, 48/pallet

RkJQdWJsaXNoZXIy MTIxNDc=