MASCO Catalog: Concrete Forming & Accessories

197 MASONS SUPPLY COMPANY Oregon (800) 537-3407 ♦ Washington (800) 537-6216 Clackamas | Eugene | West Eugene | Hillsboro | Medford | Portland | Salem | Ridgefield | Seattle | Tacoma | Woodinville M A S C O . N E T TILT-UP/PRECAST TILT-UP Brace Anchor Slab Anchors are 3/4" diameter inserts designed for anchoring wall braces to the floor slab. Slab Anchors have two legs that are pushed into the subgrade. Slab Anchors are designed for use in concrete slabs with a minimum thickness of 5" and minimum strength of 2,500 psi. Care must be taken when positioning the anchors. The horizontal strut bends must rest atop the subgrade for proper positioning. Do not allow the bends to be pushed into subgrade. Single Pick-up Insert Used for fixing braces, attaching strongbacks and lifting. Wire legs have plastic tips and insert has a locator plug to locate the fixing point when the panel is erected. Minimum 15" edge distance is highly recommended or loads have to be reduced. Approximate 2:1 safety factor rating in 2500 psi concrete. Double Pick-up Insert Plastic tipped and have locater plugs installed. Available in 1" and 1-1/2" diameter. Spaced 12" and15" from center. Used in combination with angle lifting plate. Minimum coil penetration for 1" is 2-1/2" and for 1-1/2" is 3". Approximate 2:1 safety factor rating in 2,500 psi concrete. No. Size Wt (lbs) DS T11512 1" x 5-1/2" 1.31 DS T116 1" x 6" 1.33 DS T11146 1-1/4" x 6" 1.92 DS T11147 1-1/4" x 7" 1.95 Other sizes available on request. No. Size Wt (lbs) DS T216 1" x 6" 3.04 DS T21612 1" x 6-1/2" 3.06 DS T217 1" x 7" 3.10 Other sizes available on request. No. Size Wt (lbs) DS T45 5" 1.00 DS T46 6" 1.25 PLASTIC INSERT COIL .250" SLAB THICKNESS