CASTinTACT® Concrete Tactile Warning Panels
-15- MASCO CASTinTACT ® DETECTABLE WARNING 36" BLENDED TRANSITION - THIN SET INSTALLATION 2% SLOPE 5% SLOPE MAX ½” E.J. A A ½” E.J. 6” TYP. 5% MAX. Ø LIP GUTTER 225 (9") 300 (12") THICKEN SLAB UNDER TACTILE PANEL MONOLITHIC CURB & SIDEWALK SECTION A-A SECTION A-A BLOCKOUT THIN SET ½” P.J. or E.J. 3/16 ” P.J. 3/16 ” P.J. SECTION B 3/16” P.J. 3/16” P.J. ½” E.J. THIN SET E.J. E.J. ½” E.J. ½” E.J. ½” P.J. or E.J. THIN SET INSTALLATION E.J. = EXPANSION JOINT P.J. = PANEL JOINT 1. PLACE TRUNCATED DOME DETECTABLE WARNING PANEL AT THE BASE OF CURB RAMP. INSTALL ACROSS FULL WIDTH OF RAMP A MINIMUM 610 mm (24") IN DEPTH A SET BACK 200mm (8") FROM BOTTOM OF CURB. 2. SIDEWALK CURB RAMP SLOPES SHOWN ARE RELATIVE T THE TRUE LEVEL HORIZON (ZERO BUBBLE). 3. SIDE FLARES THAT ARE NOT PART OF THE PATH OF TRAV MAY BE ANY SLOPE. 4. EXPANSION JOINTS ARE REQUIRED AT ALL SIDEWALK RA SLOPE BREAKS. 5. SIDEWALK FLARE IS NOT NECESSARY WHERE THE RAMP PROTECTED FROM PEDESTRIAN CROSS-TRAVEL. 6. THICKEN CONCRETE UNDER DETECTABLE WARNING PAN B SLOPE FLARE SLOPES 10% FOR LANDINGS 1220mm (48") OR WIDER ½” E.J. ½” E.J. 914 (36") 162 (6.5") B ½” E.J. SLOPE REGISTERED PROFESSIONAL ENGINEER NOT BE USED WITHOUT CONSULTING A RESPONSIBILITY OF THE USER AND SHOULD PRINCIPLES AND PRACTICES, IS THE SOLE GENERALLY ACCEPTABLE ENGINEERING WHILE DESIGNED IN ACCORDANCE WITH THE SELECTION AND USE OF THIS DRAWING ½” E.J. 2% SLOPE 5% SLOPE MAX ½” E.J. A A ½” E.J. 6” TYP. 5% MAX. Ø LIP GUTTER 225 (9") 300 (12") THICKEN SLAB UNDER TACTILE PANEL MONOLITHIC CURB & SIDEWALK SECTION A-A SECTION A-A BLOCKOUT THIN SET ½” P.J. or E.J. 3/16 ” P.J. 3/16 ” P.J. SECTION B 3/16” P.J. 3/16” P.J. ½” E.J. THIN SET E.J. E.J. ½” E.J. ½” E.J. ½” P.J. or E.J. MASCO CASTinTACT ® | 36” BLENDED TRANSITION THIN SET INSTALLATION B SLOPE FLARE SLOPES 10% FOR LANDINGS 1220mm (48") OR WIDER ½” E.J. ½” E.J. ½” E.J. 2% SLOPE ½” E.J. A A ½” E.J. 6” TYP. 5% MAX. Ø LIP GUTTER 225 (9") 300 (12") THICKEN SLAB UNDER TACTILE PANEL MONOLITHIC CURB & SIDEWALK SECTION A-A SECTION A-A BLOCKOUT THIN SET ½” P.J. or E.J. 3/16 ” P.J. SECTION B 3/16” P.J. 3/16” P.J. ½” E.J. THIN SET ½” E.J. ½” E.J. MASCO CASTinTACT ® | 36” BLENDED TRANSITION THIN SET INSTALLATION B SLOPE FLARE SLOPES 10% FOR LANDINGS 1220mm (48") OR WIDER ½” E.J. ½” E.J. GENERAL NOTES 1. PLACE TRUNCATED DOME DETECTABLE WARNING PANELS AT THE BASE OF CURB RAMP. INSTALL ACROSS FULL WIDTH OF RAMP A MINIMUM 610 mm (24") IN DEPTH AND SET BACK 200mm (8") FROM BOTTOM OF CURB. 2. SIDEWALK CURB RAMP SLOPES SHOWN ARE RELATIVE TO THE TRUE LEVEL HORIZON (ZERO BUBBLE). 3. SIDE FLARES THAT ARE NOT PART OF THE PATH OF TRAVEL MAY BE ANY SLOPE. 4. EXPANSION JOINTS ARE REQUIRED AT ALL SIDEWALK RAMP SLOPE BREAKS. 5. SIDEWALK FLARE IS NOT NECESSARY WHERE THE RAMP IS PROTECTED FROM PEDESTRIAN CROSS-TRAVEL. 6. THICKEN CONCRETE UNDER DETECTABLE WARNING PANEL. THE SELECTION AND USE OF THIS DRAWING WHILE DESIGNED IN ACCORDANCE WITH GENERALLY ACCEPTABLE ENGINEERING PRINCIPLES AND PRACTICES, IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. Download more ramp drawings online at www.CASTinTACT.com
Made with FlippingBook
RkJQdWJsaXNoZXIy MTIxNDc=