CASTinTACT® Concrete Tactile Warning Panels
-10- Predetermine measurements prior to cutting, oversize all sides minimum 2" each direction. Prepare a well drained and properly compacted subgrade. Dowel into existing concrete as necessary. Oversize area minimum 2" in each direction. Place CASTinTACT ® into fresh concrete 6-8" from curb line and set panels with a rubber mallet. Wedge or flared edge of panel facing the curb. 2" minimum new concrete all sides. Pre-dampen and parge back of panel with CASTinTACT ® Wet Set PreMix or fresh concrete. Concrete shall be poured, leveled, floated and recessed 7/8" below finish grade. Fill perimeter with concrete, level with base of domes, edge panels, and finish to specifications. Clean up is fast and easy with stainless steel brush and hydra sponge. CASTinTACT ® - THE DEPENDABLE CONCRETE SOLUTION! Full Depth Retrofit Install US Patent No 7,000,361 & 7,121,048 And Other Patents Pending. 1 3 5 7 2 4 6 8 CAST inTACT .com JAN 2010